-40%

N1201SA UV RF Vector Impedance SWR Antenna Analyzer Meter Tester 34MHZ-2.7GHz

$ 62.83

Availability: 501 in stock
  • Item must be returned within: 30 Days
  • Brand: Unbranded
  • Modified Item: No
  • MPN: Does Not Apply
  • Frequency Range: 34.375MHZ-2.7GHz
  • Country/Region of Manufacture: China
  • All returns accepted: Returns Accepted
  • Refund will be given as: Money Back
  • Custom Bundle: No
  • Return shipping will be paid by: Buyer
  • Condition: New

    Description

    Description
    RF Vector Antenna Analyzer SWR Meter 34.375MHZ-2.7GHz For Resistance Impedance SWR S11 PS200 N1201SA+
    Description:
    This instrument has four interfaces: single point measurement, scanning, system information, correction and calibration.
    The default boot into single-point measurement interface.
    Note: For the convenience of users, each time calibration correction options will automatically change to users' calibration. Meanwhile, in order to ensure the integrity of the calibration, the calibration process, the automatic shutdown function fails, the consistent boot.
    Startup and Shutdown:
    Hold down the CTRL key off press the power switch button.
    The boot state, long press (2S above) the switch button, after the release, the instrument will shut down.
    The boot state, long press (2S above) the switch button, after the release, the instrument will shut down.
    Attention:
    You need to hold down the second key and the fourth key at the same time to turn it on.
    Recommended Usages:
    1.In order to ensure the accuracy of measurement and calibration, preheat the instrument at least 15 minutes.
    2.Try to use good quality RF cable and connectors.
    3.Calibrated cable marked to the next may not need to calibrate and direct use.
    4.Test cable process affect the measurement accuracy, it is recommended that, where possible, do not choose too long test cable.
    5.Before measurement and calibration, make sure you are not in a strong wireless signal, so as to avoid interference caused by inaccurate measurements.
    6.If the impedance measurements themselves do not understand, you can refer to a vector network analyzer instructions and tutorials. This instrument is equivalent to a single-port vector network analysis.
    Specifications:
    - Frequency: 34.375MHZ-2.7GHz
    - Spacing: 1kHz
    - Display: 2.4-inch TFT Pixel 320x240 (QVGA)
    - Nominal Capacity: 2000mAH(7.4Wh)
    - Power Dissipation: <1.5W
    - Charging Current: 400mA
    - Charging Port: USB(For charging only)
    - Automatic Power Off: Adjustable(Always on; 5mins~60min)
    - Measure Facts: Resistance/reactance/SWR/s11
    - Resolution Ratio: 4bits effective digits
    - Frequency Accuracy: ±5ppm
    - Connector: SMA-K
    - Measuring Range:
    * Impedance: 0.1Ω~1000Ω(Absolute value of impedance);
    * SWR: 1.000~65;
    * s11(dB): 0dB to -60dB
    - Error (single point measurement):
    * Impedance: * SWR: * s11 (dB/°): 0.1 dB /5° (0dB to -10dB); 1 dB /10° (-10dB to -20dB); 5dB/20° (-20dB to -40dB)
    - Directivity: <35dB(35MHz~2GHz after calibration); <30dB(2GHz~2.7GHz)
    - Scan Points: 280
    - Output Level: -18dBm
    - Working Temperature: 0℃~40℃
    - Atmospheric Pressure: 860hPa~1060hPa
    - Dimensions: 98 x 86 x 30mm
    Package Included:
    - 1 x Set of Antenna Analyzer
    Note: Please note that the original model number of this item is N1201SA+.
    Payment Terms
    1.We accept PayPal only.
    2.All major credit cards are accepted through secure payment processor PayPal.
    3.Payment must be received within 7 business days of auction closing.
    4.We ship to your eBay or Paypal address. Please make sure your eBay and Paypal address is correct before you pay.
    Shipping Terms
    - For remote regions, we will charge your extra shipping costs. Usually it cost about 35USD-50USD. We will contact you after your payment. Thanks for your understanding.
    Return Terms
    1. If you receive defective item, please kindly notify us within 14 days. We will guide you the returning instruction for replacement or refund.
    2. If you purchased in improper condition, please NOTE that the sipping and handling fee will not be refund, all return shipping fee should paid by the buyer unless item DOA.
    3. We reserve the right to refuse any returns for objective reasons.
    Custom Duties & Taxes
    1. Import duties, taxes, and charges are not included in the item price or postage cost. These charges are the buyer's responsibility.
    2. Avoiding some unnecessary trouble, please check with your country's customs office to inform us what we should declare its value before shipping.
    Feedback
    1. If you are dissatisfied for any reason, please don't be quick to leave us neutral or negative feedback. We work hard to make sure EVERY CUSTOMER 100% SATISFIED and resolve any problem for you and always leave positive feedback to all our customers.
    2. If you are satisfied with the product you received, please kindly leave us a positive feedback and 5 star DSR. If there is any problem of your order, please feel free to contact us firstly, we are responsible and credible seller, will follow it for you asap.
    On Aug-24-20 at 02:57:02 PDT, seller added the following information: